The smoke generator is interchangeable with the dryer. After finishing the drying phase, add a step with an action. This prevents the controller from automatically turning on the smoke generator without physically swapping the dryer for the generator.
Step | Time | Temp | Probe 1 | Probe 2 | Smoke | Dryer | Action |
---|---|---|---|---|---|---|---|
1 | ∞ | 50 °C | 30 °C | — | OFF | ON | — |
2 | ∞ | OFF | — | — | OFF | OFF | Replace dryer/generator |
3 | ∞ | 80 °C | 65 °C | — | ON | OFF | — |
Note: the smoke generator and the dryer work alternately.
To keep the meat warm after it reaches the target temperature, add a step with a temperature of about 50 °C.
Step | Time | Temp | Probe 1 | Smoke | Dryer | Action |
---|---|---|---|---|---|---|
1 | ∞ | 120 °C | 65 °C | ON | OFF | — |
2 | ∞ | 50 °C | OFF | OFF | OFF | — |
For two portions using two probes, set separate target temperatures.
Step | Time | Temp | Probe 1 | Probe 2 | Smoke | Dryer | Action |
---|---|---|---|---|---|---|---|
1 | ∞ | 120 °C | 65 °C | 70 °C | ON | OFF | x |
2 | ∞ | 120 °C | 65 °C | 70 °C | ON | OFF | Remove the meat |
When smoking takes several days or you want longer breaks between sessions.
Plan: 2 × 6 hours of smoking with a 12-hour break.
Step | Time | Temp | Probe 1 | Probe 2 | Smoke | Dryer | Action |
---|---|---|---|---|---|---|---|
1 | 6 h | OFF | OFF | OFF | ON | OFF | x |
2 | 12 h | OFF | OFF | OFF | OFF | OFF | x |
3 | 6 h | OFF | OFF | OFF | ON | OFF | x |
Plan: 5 days — 2 h smoking + 22 h break each day (10 steps total).
Step | Time | Temp | Probe 1 | Probe 2 | Smoke | Dryer | Action |
---|---|---|---|---|---|---|---|
1 | 2 h | OFF | OFF | OFF | ON | OFF | x |
2 | 22 h | OFF | OFF | OFF | OFF | OFF | x |
3 | 2 h | OFF | OFF | OFF | ON | OFF | x |
4 | 22 h | OFF | OFF | OFF | OFF | OFF | x |
5 | 2 h | OFF | OFF | OFF | ON | OFF | x |
6 | 22 h | OFF | OFF | OFF | OFF | OFF | x |
7 | 2 h | OFF | OFF | OFF | ON | OFF | x |
8 | 22 h | OFF | OFF | OFF | OFF | OFF | x |
9 | 2 h | OFF | OFF | OFF | ON | OFF | x |
10 | 22 h | OFF | OFF | OFF | OFF | OFF | x |
Legend: ∞ – no time limit, OFF – off, ON – on, x – no action.